Description of the units
4
Function Description
Power Off
Input signalling that the press brake is in setup mode.
Power Off = 1: Setup mode activated
All safety functions are deactivated in setup mode.
– The display is switched on.
– The OSSD LED on the receiver lights up red.
– The light source is switched off.
Acknowledgement
Input to acknowledge that a press stroke is to be performed with a
reduced protected field (front and/or rear segments blanked). The
protected field mode selected is shown on the receiver's display.
Acknowledgement = 0/1 pulse edge via pushbutton: Run selected
protected field mode
Protected field mode 1/protected field mode 2
Two safe inputs for setting the protected field mode. The CNC or
safety system provides the signal. It is only absolutely necessary to
connect the inputs to a safety system if communication is needed for
tool detection.
Funktion_Geraete_Empfaenger_Eingaenge_Schutzfeldmodus_Biegewinkel_Info
INFORMATION
The Power Off input has another function during the system sta-
tus TEST. It is used for communication with the safety system.
See "Communication with a safety system" in this section.
Protected
field mode
Bending function
1
2
0
0
Standard
1
0
Box bending
0
1
Bending with back gauge
1
1
Box bending with back gauge
INFORMATION
The inputs for protected field mode have another function during
the system status TEST. They are used for communication with
the safety system. See "Communication with a safety system" in
this section.