5.2
Install transmitter and receiver
5
Installation
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
5-2
5.2
Install transmitter and receiver
5200
Install transmitter and receiver
5-
Montage_Sender_Empfaenger_Zusatz
Fastening kits for the transmitter and receiver are available as acces-
sories (for order no. see Chapter 11, "Technical Details").
Montage_Sender_Empfaenger
The fastening kit consists of an adapter plate and adjustment plate
with a slot nut. The bracket on the upper die must have a correspond-
ing groove in which to insert the slot nut (see Fig. 5-1).
Fig. 5-1:
Dimensions of adapter plate with groove, dimensions in
mm
14+0,3
7+0,3
15
+0,2
8,3
+0,2
1
17+0,5
(4x) ø15
(4x) ø8.4
(32)
5
(71.5)
115
35
35
27
A-A
B