4function description, 4 description of the units – Pilz PSENvip RL D P User Manual
Page 52

4.4
Description of the units
4
Function Description
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
4-24
1
– The PSENvip starts communication.
Activate = 0/1 pulse edge
– Tool class PLC -> PSENvip Bit 1/2: Bits can have any status
2
– The safety system is ready for communication.
PLC Ready = 0/1 pulse edge
– Tool class PLC -> PSENvip Bit 1/2 = 0 to step 5
3
The PSENvip sends the detected tool class to the safety system.
4
The PSENvip confirms the validity of the tool class registered on the
safety system in step 3.
Acknowledge PSENvip -> PLC = 0/1 pulse edge
5
– The safety system reflects the tool class transmitted by the PSEN-
vip.
– Tool class PLC -> PSENvip Bit 1/2 = 0 or 1, depending on the tool
class
6
The PSENvip ends communication.
All outputs are set = 0:
– Activate = 0
– Acknowledge PSENvip -> PLC = 0
– Tool class PSENvip -> PLC Bit 1 = 0
– Tool class PSENvip -> PLC Bit 2 = 0
Tool class
1
2
3
Tool class PSENvip -> PLC Bit 1
0
1
1
Tool class PSENvip -> PLC Bit 2
1
0
1
Tool class
1
2
3
Tool class PLC -> PSENvip Bit 1
0
1
1
Tool class PLC -> PSENvip Bit 2
1
0
1