4.4

Description of the units

4

Function Description

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

4-18

4.4.3.3

LED

LED

4-

Funktion_Geraete_Empfaenger_LED_OSSD

OSSD

The OSSD LED on the receiver indicates the status of the protected
field.
Green: The protected field is clear
Red: Protected field is interrupted

Funktion_Geraete_Empfaenger_LED_Biegewinkelmessung

Bending angle measurement

The bending angle measurement LED indicates the result of the
bending angle measurement.
LED blue: Bending angle measurement is within the tolerance
off: Measured angle is outside the tolerance, measuring function is
inactive

Funktion_Geraete_Empfaenger_LED_RL_D_M_Abbildung

Fig. 4-8:

LED on receiver

1: OSSD LED

2: Bending angle measurement LED

2

1