4.7

System cycle

4

Function Description

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

4-34

3

4

5

State

Downward movement
Creep speed mode signal

Foot switch

1

System-Init

0

OSSD

1

Creep speed mode SG

1

Protected field

Free

State

Bottom dead centre

Foot switch

1

System-Init

0

OSSD

0

Creep speed mode SG

1

Protected field

Interrupted

State

Upward movement
Rapid traverse

Foot switch

1

System-Init

1

OSSD

1 or 0

Creep speed mode SG

0

Protected field

Free or interrupted

v = 0

v > 10 mm/s

v £ 10 mm/s

v = 0

v = 0

v > 10 mm/s

v £ 10 mm/s

v = 0

v = 0

v > 10 mm/s

v £ 10 mm/s

v = 0