4function description, 7 system cycle – Pilz PSENvip RL D P User Manual
Page 62

4.7
System cycle
4
Function Description
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
4-34
3
4
5
State
Downward movement
Creep speed mode signal
Foot switch
1
System-Init
0
OSSD
1
Creep speed mode SG
1
Protected field
Free
State
Bottom dead centre
Foot switch
1
System-Init
0
OSSD
0
Creep speed mode SG
1
Protected field
Interrupted
State
Upward movement
Rapid traverse
Foot switch
1
System-Init
1
OSSD
1 or 0
Creep speed mode SG
0
Protected field
Free or interrupted
v = 0
v > 10 mm/s
v £ 10 mm/s
v = 0
v = 0
v > 10 mm/s
v £ 10 mm/s
v = 0
v = 0
v > 10 mm/s
v £ 10 mm/s
v = 0