4function description, 4 description of the units – Pilz PSENvip RL D P User Manual
Page 51

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
4-23
4.4
Description of the units
4
Function Description
Key to inputs and outputs:
Funktion_Kommunikation_Ablauf
Communication sequence:
Terminal
Input/output
Normal mode
Communication with safety sys-
tem
Notes
X1, 6
Output
No function
Activate
The PSENvip starts com-
munication.
X2, 6
Output
No function
Acknowledge PSENvip -> PLC
The PSENvip confirms
the validity of the tool
class registered on the
safety system.
X1, 1
Output
Overrun measure-
ment 1
Tool class PSENvip -> PLC Bit 1
The PSENvip sends Bit 1
of the detected tool class
to the safety system.
X2, 1
Output
Overrun measure-
ment 2
Tool class PSENvip -> PLC Bit 2
The PSENvip sends Bit 2
of the detected tool class
to the safety system.
X2, 2
Input
Power Off
PLC Ready
The safety system is
ready for communication.
X1, 3
Input
Protected field
mode 1
Tool class PLC -> PSENvip Bit 1
The safety system re-
flects Bit 1 of the tool
class.
X1, 4
Input
Protected field
mode 2
Tool class PLC -> PSENvip Bit 2
The safety system re-
flects Bit 2 of the tool
class.
PLC Ready
1
0
1
0
1
0
1
0
1
0
Activate
Acknowledge PSENvip -> PLC
1
0
Tool class PSENvip -> PLC Bit 1
1
0
Tool class PSENvip -> PLC Bit 2
Tool class PLC -> PSENvip Bit 1
Tool class PLC -> PSENvip Bit 2
1
2
3
4
5
6
7
max. 600 ms
max.
200 ms
max.
200 ms
max.
200 ms