beautypg.com

4function description, 4 description of the units – Pilz PSENvip RL D P User Manual

Page 49

background image

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

4-21

4.4

Description of the units

4

Function Description

Status of the OSSD

Funktion_Display_Betriebszustand_mit_Biegewinkelmessung

Operating status

Funktion_Display_Eingabefeld

The input and display field is used to

Display the active protected field mode

See chapter 8, "Operation"

Enter the overrun

See chapter 7, "Commissioning"

Menu Selection

Display the adjustment image during initial commissioning

See chapter 7, "Commissioning"

Status

Description

OSSD ON

The output signal switching devices OSSD1 and OSSD2
are in the ON state.
The protected field is clear.

OSSD OFF

The output signal switching devices OSSD1 and OSSD2
are in the OFF state.
The protected field is interrupted. Or the PSENvip is not in
the status: SYSTEM OK or NORMAL OPERATION

Status

Description

NORMAL OP-
ERATION

One of the protected field modes is activated, the overrun
is being monitored.
See chapter 8, "Operation"

SETUP

This is the operating mode in which you enter the overrun.
See chapter 7, "Commissioning"

TOOL CHANGE

This is the operating mode in which you track the adjust-
ment line to the tip of the tool during a tool change.
See chapter 7, "Commissioning"

ADJUSTMENT

This is the operating mode in which you set up the trans-
mitter and receiver mechanically so that they are calibrated
with each other.
See chapter 7, "Commissioning"

DIAGNOSTICS

System data and error codes are displayed in this menu.
Pilz technical support can use these to locate errors.
See Chapter 9, "Diagnostics and Troubleshooting"

MEASURE-
MENT

This is the operating mode in which the bending angle
measurement is parameterised and displayed.
See chapter 7, "Commissioning", chapter 8, "Operation"

MENU

On pressing the key, you can choose between
the following
options:
- TOOL CHANGE: Adjustment during tool change
- ADJUSTMENT: Adjustment during initial commissioning
- DIAGNOSTICS: Display error codes
- MEASUREMENT: Set the parameters for and display the
bending angle measurement