Technical details, 11 technical details, 1 technical details – Pilz PSENvip RL D P User Manual
Page 149

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
11-1
11.1
Technical Details
11
Technical Details
11
11000
Technical Details
Technical Details
11-
11.1
Technical Details
11100
Technical Details
11-
Technische Daten PSENvip RL D M
Technical details
Function
Camera-based protection system with integrated overrun
measurement
Application area
IEC 61496-1,-2, prEN 12622, IEC 61508
Detection zone
Length
0.1 m … 10 m
Height
Max. 20 mm
Width
44 mm
Reaction time
4 ms
Category
Type 4 in accordance with IEC 61496-1
Resolution of protected field
Object size
7 mm
Overrun
2 mm
Required penetration depth
From side
1.6 mm
From top or bottom
1.6 mm
Overrun measurement
2 mm … 14 mm
Transmitter's electrical data
Number of inputs
2
Supply voltage
24 VDC
Tolerance range
20 V … 30 VDC including residual ripple of max. ± 1.2 V
Current consumption
0.2 A at 24 VDC
Connection type
M12, 4-pin
Cable cross section
Min. 0.14 mm
Light source
High Power LED
Service life
50 000 hours
Diameter of illuminated target area
70 mm
Receiver's electrical data
Supply voltage
24 VDC
Tolerance range
20 V … 30 VDC including residual ripple of max. ± 1.2 V
Current consumption
Max. 2 A at 24 VDC
Connection type
2 x M12, 8-pin
Inputs on the receiver
Number
5
Galvanic isolation
No
Signal level at "0"
-3 V … +5 VDC
Signal level at "1"
+15 V … +30 VDC
Input current
Typ. 6 mA
Recognition time
Min. 100 ms
Outputs on the receiver
Number of positive-switching single-pole semiconductor
outputs
8
Galvanic isolation
No
Output current at "1"
Max. 0.25 A at 24 VDC
Permitted range
0 ... 0.32 A
Short circuit protection
Electronic
Min. pulse width at "0" signal (off time)
100 ms
Max. cable length with cable cross section 0.25 mm
2
150 m