802.1x Commands

331

discard-shutdown — Discard frames with source addresses that are not the supplicant
address, and shut down the port.

trap seconds— Send SNMP traps and specifies the minimum time in seconds between
consecutive traps. (Range: 1- 1000000

)

Default Configuration

Discard frames with source addresses that are not the supplicant address. No traps.

Command Mode

Interface Configuration (Ethernet) mode

User Guidelines

This command is relevant when Multiple Hosts is disabled and the user has been
authenticated successfully.

Example

The following example uses forward action to forward frames with source addresses that are
not the supplicant address.

console(config-if-1/g1)#dot1x single-host-violation forward trap

100

show dot1x advanced

Use the show dot1x advanced command in Privileged EXEC mode to display 802.1x advanced
features for the switch or for the specified interface.

Syntax

show dot1x advanced [ethernet interface]

interface — Specifies a valid ethernet interface.

Default Configuration

This command has no default configuration.

Command Mode

Privileged EXEC mode

User Guidelines

This command has no user guidelines.