beautypg.com

Controller error recovery model, Troubleshooting – Rockwell Automation 1761 MicroLogix 1000 Programmable Controllers User Manual

Page 273

background image

Troubleshooting Your System

14–5

Controller Error Recovery Model

Use the following error recovery model to help you diagnose software and hardware
problems in the micro controller. The model provides common questions you might
ask to help troubleshoot your system. Refer to the recommended pages within the
model and to S:6 of the status file on page B–14 for further help.

Start

Identify the error code

and description.

Refer to appendix B for

probable cause and

recommended action.

Return controller to

REM RUN or any of

the REM Test modes.

Clear fault using either

function key F9 or F10.

Place the controller in

REM PROGram mode.

Correct the condition

causing the fault.

Test and verify system

operation.

Tighten wire

connections.

Check power.

Does the

controller have power

supplied?

Refer to page 14–3

for probable cause and

recommended action.

Is the error hardware

related?

Are the wire

connections tight?

Is the Power

LED On?

Is the Run LED On

constantly?

Is an input or

output LED showing

proper status?

Refer to page 14–4

for probable cause and

recommended action.

No

Yes

No

No

No

Yes

Yes

Yes

Yes

Is the Fault LED On?

No

No

Yes

Refer to page 14–3

for probable cause and

recommended action.

Yes

No

Troubleshooting