00 . 14 terminations technology, Screw terminal – Northern Connectors Harting HAN Industrial Rectangular Connectors User Manual
Page 20

Han
00
.
14
Terminations technology
Screw terminal
Screw terminals meet VDE 0609 /EN 60 999. Dimensions and
tightening torques for testing are shown in following table.
Screw dimensions and tightening torque for screw terminals
Wire gauge (mm²)
1.5
2.5
4
6
10
16
Screw thread
M3
M3
M3.5
M4
M4
M6
Test moment of torque
(Nm)
0.5
0.5
0.8
1.2
1.2
1.2*
min. pull-out for stranded
wire (N)
40
50
60
80
90
100
* for screws without heads
The relevant regulations state that in the case of
● Terminals with wire protection
the use of ferrules is not necessary. Series Han E
®
,
Han
®
HsB, Han Hv E
®
, Han
®
K 6/12, Han
®
K 6/6
● Terminals without wire protection
The insulation is first stripped and then a wire ferrule must be
used.
Series Han
®
K 4/x, Han A
®
, Staf
®
Screw terminal
Inserts
Wire protection
min. wire gauge
max. wire gauge*
Stripping length
Yes
No
mm²
AWG
mm²
AWG
mm
Han
®
3 A, Han
®
4 A
X
0.75
18
1.5
16
4.5
Han
®
10 A, 16 A, 32 A
X
0.75
18
2.5
14
7.5
Han E
®
, Hv E
®
X
0.75
18
2.5
14
7.5
Han
®
HsB
X
1.5
16
6
10
11.5
Han
®
K 6/6, K 6/12
(signal contacts)
X
0.2
24
2.5
14
7.5
Han
®
K 4/2, K 4/8
(signal contacts)
X
0.5
20
2.5
14
7.5
Han
®
K 4/0, K 4/2, K 4/8
(power contacts)
X
1.5
16
16
6
14
Han E
®
AV, Han D
®
AV
X
0.2
24
2.5
14
8 ... 11
Staf
®
X
0.5
18
1.5
16
4.5
* Rated wire gauge according to DIN EN 60 999-1