Han® k 6/12, K 6/12, K 6/12 features – Northern Connectors Harting HAN Industrial Rectangular Connectors User Manual
Page 122: Technical characteristics
05
.
10
Han
Com
Han
®
K 6/12
Features
• Combination of power and signal area in one
connector
• Axial screw termination for power area
• Screw termination for signal area
Assembly instructions see page 05.23
Current carrying capacity
The current carrying capacity of the connectors is limited by the
thermal load capability of the contact element material including
the connections and the insulating parts. The derating curve
is therefore valid for currents which flow constantly (non-inter-
mittent) through each contact element of the connector evenly,
without exceeding the allowed maximum temperature.
Measuring and testing techniques according to
DIN EN 60 512-5-2
Operating current
Ambient temperature
Wire gauge:
➀ 10 mm²
➁ 6 mm²
➂ 4 mm²
Technical characteristics
Specifications
DIN EN 60 664-1
DIN EN 61 984
Approvals
,
,
Inserts
Number of contacts
6 / 12 + PE
Electrical data
acc. to EN 61 984
Power area
40 A 690 V 8 kV 3
Rated current
40 A
Rated voltage
690 V
Rated impulse voltage
8 kV
Pollution degree
3
Signal area
10 A 230/400 V 4 kV 3
Rated current
10 A
Rated voltage conductor - ground 230 V
Rated voltage conductor - conductor 400 V
Rated impulse voltage
4 kV
Pollution degree
3
Rated voltage
acc. to UL/CSA
600 V / 300 V
Insulation resistance
≥ 10
10
Ω
Material polycarbonate
Limiting temperatures
-40 °C ... +125 °C
Flammability acc. to UL 94
V 0
Mechanical working life
- mating cycles
≥ 500
Contacts
Power contacts
Material
copper alloy
Surface
- hard-silver plated
3 µm Ag
Contact resistance
≤ 0.5 mΩ
Axial screw termination
- geometric wire gauge
2.5 ... 10 mm²
- AWG
14 ... 8
Max. insulation diameter
6.1 mm
Tightening tourque
mm² 2.5 4
6 10
Nm 1.5 1.5 2
2
Stripping length
mm² 2.5 4
6 10
mm 5
+1
5
+1
8
+1
8
+1
Signal contacts
Material
copper alloy
Surface
- hard-silver plated
3 µm Ag
Contact resistance
≤ 3 mΩ
Screw terminal
- geometric wire gauge
0.2 ... 2.5 mm²
- AWG
24 ... 14
Tightening tourque
0.5 Nm
Stripping length
7.5 mm
Hoods/Housings
see chapter 31