beautypg.com

Han® k 8/0, K 8/0, K 8/0 features – Northern Connectors Harting HAN Industrial Rectangular Connectors User Manual

Page 132: Technical characteristics

background image

05

.

20

Han

Com

Han

®

K 8/0

Features

• Axial screw termination for power area

• No signal contacts

Assembly instructions see page 05.25

Current carrying capacity

The current carrying capacity of the connectors is limited by the

thermal load capability of the contact element material including

the connections and the insulating parts. The derating curve

is therefore valid for currents which flow constantly (non-inter-

mittent) through each contact element of the connector evenly,

without exceeding the allowed maximum temperature.

Measuring and testing techniques according to

DIN EN 60 512-5-2

Operating current

Ambient temperature

Wire gauge:

➀ 25 mm²
➁ 16 mm²
➂ 10 mm²

Technical characteristics

Specifications

DIN EN 60 664-1

DIN EN 61 984

Approvals

Inserts

Number of contacts

8 + PE

Electrical data

acc. to EN 61 984

Power area

100 A 690 V 8 kV 3

Rated current

100 A

Rated voltage

690 V

Rated impulse voltage

8 kV

Pollution degree

3

Pollution degree 2 also

100 A 1000 V 8 kV 2

Rated voltage

acc. to UL

600 V

Rated current acc. to UL

82 A

Insulation resistance

≥ 10

10

Ω

Material polycarbonate

Limiting temperatures

-40 °C ... +125 °C

Flammability acc. to UL 94

V 0

Mechanical working life

- mating cycles

≥ 500

Contacts

Material

copper alloy

Surface

- hard-silver plated

3 µm Ag

Contact resistance

≤ 0.5 mΩ

Axial screw termination

- geometric wire gauge

10 ... 25 mm²

- AWG

7 ... 3

Max. insulation diameter

11.4 mm

Tightening tourque

mm² 10 16 25

Nm 6

6

7

Stripping length

13

±1

mm

Hoods/Housings