beautypg.com

11 entry of machine parameters, Commissioning – Lenze ECSCMxxx User Manual

Page 138

background image

Commissioning

Entry of machine parameters

6

l

138

EDBCSXM064 EN 11.0

6.11

Entry of machine parameters

The GDC parameter menu includes the codes for machine parameters (e.g. deceleration
time for quick stop or maximum speeds) under Motion

W Machine parameter.

ECSXA535

Fig. 6−14

GDC view: Short setup, entry of machine parameters

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C0011 Nmax

3000

Maximum speed

500

{1 rpm}

16000 Reference value for the absolute

and relative setpoint selection
for the acceleration and
deceleration times.
For parameter setting via
interface: greater changes in one
step should only be made when
the controller is inhibited (CINH)!

C0022 Imax current

à

I

max

limit

0

{0.01 A}

à

Device−dependent list

Max. current can be gathered
from the technical data.

C0105 QSP Tif

0.0

Deceleration time for quick stop
(QSP)

^ 173

0.000

{0.001 s}

999.999 Relating to speed variation n

max

(C0011) ...0 rev./min.

C0596 NMAX limit

5500

Maximum system speed

^ 250

0

{1 rpm}

16000

C0909 speed limit

1

Limitation of direction of
rotation for speed setpoint

1

−175 ... +175 %

2

0 ... +175 %

3

−175 ... 0 %

C3030 FolloErrWarn

400000

Following error limit for enabling
a warning

^ 170

0

{1 inc}

2140000000

C3031 FolloErrFail

800000

Following error limit for enabling
a FAIL−QSP
(Quick stop (QSP) is executed.)

^ 170

0

{1 inc}

2140000000

This manual is related to the following products: