beautypg.com

Appendix, Code table – Lenze ECSCMxxx User Manual

Page 327

background image

Appendix

Code table

12

l

327

EDBCSXM064 EN 11.0

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C3160 ToggleErrReac

3

Toggle bit error handling

^ 136

0

TRIP

1

Message

2

Warning

3

Off

4

FAIL−QSP

C3161 ToggleErLimit

4

Toggle bit error counter limit

^ 136

0

{1 units}

65535

C3162 ToggleBitFail

0

Toggle bit error counter
Read only

0

{1 units}

65535

C3165 SyncInside

Win

0

CAN synchronisation inside the
window
Read only

^ 209

0

{1 bit}

1

C3170 NoHoming

Reac

3

Reaction, when the reference is
not known.

0

TRIP

1

Message

2

Warning

3

Off

4

FAIL−QSP

C3175 HW EndReac

4

Reaction, when a hardware limit
switch is activated.

^ 172

0

TRIP

1

Message

2

Warning

3

Off

4

FAIL−QSP

C3180 MonitorData

0

Monitor data selection
Read only

^ 133

0

{1 units}

7

C3181 MonitorData

0

Monitor data selection

^ 133

0

Free

1

MCTRL_nPos_a

Actual position (16 bits) referred
to one revolution (rotor position)

2

DINT_TO_INT
(MCTRL_dnPosSet_p)

Following error

±2

15

3

MCTRL_nNAct_a

Actual speed (n

max

= 2

14

)

4

MCTRL_nMAct_a

Actual torque (M

max

= 2

14

)

5

MCTRL_nIAct_a

Actual motor current (I

max

= 2

14

)

6

MCTRL_nDCVolt_a

Actual DC−bus voltage
(2

14

¢ 1000 V)

7

PosLatchDiff

Difference between actual
position and position at touch
probe (C6000)

C3200 Act.Fault

0

All fault indications
(TRIP, FAIL−QSP, warning, message)

Current fault
Read only

^ 270

This manual is related to the following products: