beautypg.com

Appendix, Code table – Lenze ECSCMxxx User Manual

Page 303

background image

Appendix

Code table

12

l

303

EDBCSXM064 EN 11.0

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C0475

Freely configurable code for
phase difference signals

1 FCODE DF

0

−16000

{1 rpm}

16000

2 FCODE DF

0

[C0490] Feedback pos

0

Selection of feedback system for
positioning control

^ 109

0

Resolver at X7

Standard setting

1

TTL encoder at X8

l

Sets C0419 = 0 ("Common") if
a different encoder type as
under C0419 is set here.

2

SinCos encoder at X8

3

Absolute value encoder (single−turn) at
X8

4

Absolute value encoder (multi−turn) at
X8

[C0491] X8 in/out

0

Function of X8

^ 113

^ 121

0

X8 is input

1

X8 is output

[C0495] Feedback n

0

Selection of feedback system for
speed control

^ 109

0

Resolver at X7

Standard setting

1

TTL encoder at X8

l

Sets C0419 = 0 ("Common") if
a different encoder type as
under C0419 is set here.

2

SinCos encoder at X8

3

Absolute value encoder (single−turn) at
X8

4

Absolute value encoder (multi−turn) at
X8

C0497 Nact filter

2.0

Time constant of actual speed
value

0.0

{0.1 ms}

50.0 0.0 ms = switched off

C0504 Service codes

Only the Lenze service is allowed
to make changes!

...

C0509

C0510 ProtAppFlash

0

Write−protection application
FLASH

0

No write protection

1

Write protection is active

C0517

User menu with up to 32 entries

0.00

{0.01}

7999.00

l

Enter the numbers of the
required codes into the
subcodes.
Format: xxxx.yy
– xxxx = code number
– yy = subcode of the code

l

It is not checked whether the
entered code exists.

1 User menu

51.00

C0051

MCTRL−NACT

Display of actual speed

2 User menu

54.00

C0054

Imot

Display of motor current

3 User menu

56.00

C0056

MCTRL−MSET2

Display of torque setpoint

4 User menu

0.00

Not assigned

5 User menu

0.00

Not assigned

6 User menu

183.00

C0183

Diagnostics

Display for diagnostics

This manual is related to the following products: