11 entry of machine parameters, Commissioning – Lenze ECSCMxxx User Manual
Page 138

Commissioning
Entry of machine parameters
l
138
EDBCSXM064 EN 11.0
6.11
Entry of machine parameters
The GDC parameter menu includes the codes for machine parameters (e.g. deceleration
time for quick stop or maximum speeds) under Motion
W Machine parameter.
ECSXA535
Fig. 6−14
GDC view: Short setup, entry of machine parameters
Code
Possible settings
IMPORTANT
No.
Designation
Lenze/
{Appl.}
Selection
C0011 Nmax
3000
Maximum speed
500
{1 rpm}
16000 Reference value for the absolute
and relative setpoint selection
for the acceleration and
deceleration times.
For parameter setting via
interface: greater changes in one
step should only be made when
the controller is inhibited (CINH)!
C0022 Imax current
à
I
max
limit
0
{0.01 A}
à
Device−dependent list
Max. current can be gathered
from the technical data.
C0105 QSP Tif
0.0
Deceleration time for quick stop
(QSP)
^ 173
0.000
{0.001 s}
999.999 Relating to speed variation n
max
(C0011) ...0 rev./min.
C0596 NMAX limit
5500
Maximum system speed
^ 250
0
{1 rpm}
16000
C0909 speed limit
1
Limitation of direction of
rotation for speed setpoint
1
−175 ... +175 %
2
0 ... +175 %
3
−175 ... 0 %
C3030 FolloErrWarn
400000
Following error limit for enabling
a warning
^ 170
0
{1 inc}
2140000000
C3031 FolloErrFail
800000
Following error limit for enabling
a FAIL−QSP
(Quick stop (QSP) is executed.)
^ 170
0
{1 inc}
2140000000