Commissioning

Commissioning steps (overview)
Setting of homing

6

l

98

EDBCSXM064 EN 11.0

Setting sequence:

,

Comply with ...

the safety and application instructions for multi−axis applications in the
corresponding manuals and on the systems.

)

Note!

Follow the commissioning steps in the given order!

Settings

Brief description

Detailed

information

1.

Activate controller inhibit.

l

Press the key in GDC.

l

X6/SI1 orX6/SI2 must be open (LOW).

l

Control bit 9 = 1

2.

Set homing parameters.

Set the following codes in the GDC parameter menu under
Motion

W Homing:

l

C3010 (homing mode)

l

C3011 (zero position offset with drive traversing)

l

C3012 (zero position offset without drive traversing)

l

C0935 (traversing speed of homing)

l

C0936 (deceleration time (T

i

) of homing)

^ 143

3.

Save parameters in the
controller.

Set C0003 = 1.

4.

C Select "Homing Mode".

The "homing" mode is automatically selected by the
higher−level control (PLC): C5000 = 6
The operating mode can also be set manually in the GDC
parameter menu under Motion

W Operating mode.

^ 164

D Confirm setting of

"Homing Mode".

In order that the drive performs homing, the ECSxM axis
module must write the value from C5000 into C5001 (here
C5001 = 6).
If this is not the case, set the operating mode manually in the
GDC parameter menu under Motion

W Operating mode.

5.

Enable controllers.

The controller can only be enabled by a higher−level control
(PLC).

l

Green LED is lit continuously if X6/SI1 = HIGH,
X6/SI2 = HIGH, and the controller has been enabled via
the PLC.

l

Green LED is blinking if X6/SI1 = HIGH and X6/SI2 = HIGH.
No enable via PLC.

^ 169

6.

Start homing.

The master control (PLC) set the control word bit
Ctrl1.Bit12 = 1 (TRUE).
Notes:

l

In order to interrupt homing, reset the Ctrl1.Bit12 to "0"
using the master control.

l

Homing can also be started via the parameter setting and
operating program GDC or the keypad XT if the control
interface is switched over to codes (C4010).

^ 131

ð The drive approaches the home position according to the setting in C3010.