Commissioning

Setting of homing parameters
Homing parameters

6

l

144

EDBCSXM064 EN 11.0

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C3010 HomingMode

8

Homing mode

^ 143

^ 145

0

>_Rn_MP

Selection symbolism:

l

>: Movement in pos. direction

l

<: Movement in neg. direction

l

Lp: Limit switch in pos.
direction

l

Ln: Limit switch in neg.
direction

l

Rp: Pos. edge of the reference
switch

l

Rn: Neg. edge of the reference
switch

l

MP: Zero pulse/position of
the position encoder, once per
motor revolution

l

TP: Touch probe signal

l

Mlim: mechanical limit stop
(torque limit value)

Notes:

l

When using the homing
modes 0 ... 5, set C0540 = 2.

l

The mechanical limit stop is
defined as exceedance of the
torque limit C3008 for the
duration C3009.

l

When the last action listed is
executed, the home position
is set (e.g. zero pulse with
"MP"), even if the drive
continues traversing.

l

In all modes without limit
switch ("Lp" / "Ln") retracting
from the limit switch with
error handling set in C3175 is
not possible.

1

<_Rn_MP

2

>_Lp_<_Rn_MP

3

<_Ln_>_Rn_MP

4

>_Rp_<_Rn_MP

5

<_Rp_>_Rn_MP

6

>_Rn_>_TP

7

<_Rn_<_TP

8

>_TP

9

<_TP

10

>_Lp_<_TP

11

<_Ln_>_TP

12

>_Lp_<_MP

13

<_Ln_>_MP

14

>_MP

15

<_MP

16

>_MLim

17

<_MLim

99

Set reference

C3011 Home offset

0

Offset between home position
and standstill position

^ 155

−2140000000

{1 inc}

2140000000

C3012 Measure offs.

0

Offset for shifting the zero
position with regard to the
standstill position

^ 155

−2147483647

{1 inc}

2147483647

This manual is related to the following products: