Commissioning
Setting of homing parameters
Homing parameters
l
144
EDBCSXM064 EN 11.0
IMPORTANT
Possible settings
Code
Selection
Lenze/
{Appl.}
Designation
No.
C3010 HomingMode
8
Homing mode
^ 143
^ 145
0
>_Rn_MP
Selection symbolism:
l
>: Movement in pos. direction
l
<: Movement in neg. direction
l
Lp: Limit switch in pos.
direction
l
Ln: Limit switch in neg.
direction
l
Rp: Pos. edge of the reference
switch
l
Rn: Neg. edge of the reference
switch
l
MP: Zero pulse/position of
the position encoder, once per
motor revolution
l
TP: Touch probe signal
l
Mlim: mechanical limit stop
(torque limit value)
Notes:
l
When using the homing
modes 0 ... 5, set C0540 = 2.
l
The mechanical limit stop is
defined as exceedance of the
torque limit C3008 for the
duration C3009.
l
When the last action listed is
executed, the home position
is set (e.g. zero pulse with
"MP"), even if the drive
continues traversing.
l
In all modes without limit
switch ("Lp" / "Ln") retracting
from the limit switch with
error handling set in C3175 is
not possible.
1
<_Rn_MP
2
>_Lp_<_Rn_MP
3
<_Ln_>_Rn_MP
4
>_Rp_<_Rn_MP
5
<_Rp_>_Rn_MP
6
>_Rn_>_TP
7
<_Rn_<_TP
8
>_TP
9
<_TP
10
>_Lp_<_TP
11
<_Ln_>_TP
12
>_Lp_<_MP
13
<_Ln_>_MP
14
>_MP
15
<_MP
16
>_MLim
17
<_MLim
99
Set reference
C3011 Home offset
0
Offset between home position
and standstill position
^ 155
−2140000000
{1 inc}
2140000000
C3012 Measure offs.
0
Offset for shifting the zero
position with regard to the
standstill position
^ 155
−2147483647
{1 inc}
2147483647