Appendix – Lenze ECSCMxxx User Manual
Page 312

Appendix
Code table
l
312
EDBCSXM064 EN 11.0
IMPORTANT
Possible settings
Code
Selection
Lenze/
{Appl.}
Designation
No.
C0909 speed limit
1
Limitation of direction of
rotation for speed setpoint
1
−175 ... +175 %
2
0 ... +175 %
3
−175 ... 0 %
C0910 MCTRL TP2
delay
0
MCTRL dead time compensation
TP2 (X6/DI2)
−32767
{1 inc}
32767 1 inc
º approx. 60 ms
C0911 MCTRL TP2
sel.
0
MCTRL touch probe signal source
0
Zero pulse of position encoder (C0490) X7/X8
1
Touch probe input TP2
X6/DI2
C0912 MCTRL TP2
Edge
0
MCTRL touch probe TP2 edge
(for touch probe via digital input
X6/DI2 (C0911 = 1))
0
Rising edge TP2
1
Falling edge TP2
2
Rising and falling edge TP2
3
Switched off
C0935 L_REF1 speed
100
Traversing speed of homing
^ 143
1
{1 rpm}
16000
C0936 L_REF1 Ti
1.0
Deceleration time (T
i
) of homing
^ 143
0.01
{0.01 s}
650.00
C1120 Sync mode
0
{1}
Sync signal source
^ 207
0
Off
Off
1
CAN sync
Sync connection via interface X4
(CAN)
^ 210
2
Terminal sync
Sync connection via terminal
X6/DI1
^ 211
C1121 Sync cycle
2
Synchronisation cycle
^ 207
1
{1 ms}
13
C1122 Sync phase
0.460
Synchronisation phase
^ 207
0.000
{0.001 ms}
6.500
C1123 Sync window
0.010
Synchronisation window
l
If the sync telegram/signal
sent by the master is inside
this "time slot", C3165 is set
to 1.
^ 209
0.000
{0.001 ms}
6.500