Appendix – Lenze ECSCMxxx User Manual
Page 301

Appendix
Code table
l
301
EDBCSXM064 EN 11.0
IMPORTANT
Possible settings
Code
Selection
Lenze/
{Appl.}
Designation
No.
[C0421] Encoder volt
0
Encoder voltage
^ 113
^ 121
0
5.0 V
Sets C0419 = 0 ("common") if the
value is altered.
1
5.6 V
2
6.3 V
3
6.9 V
4
7.5 V
5
8.1 V
C0426 DIS: In
Signal at DFIN input
Only display
−32767
{1 rpm}
32767
[C0427] Enc. signal
0
Function of the master frequency
input signals on X8 (DFIN)
^ 113
^ 121
0
2−phase
1
A: speed
B: direction
2
A or B: speed or direction
C0428 DFIN TP sel.
0
DFIN touch probe signal source
0
Zero pulse of position encoder (C0490) X7/X8
1
Touch probe input TP1
X6/DI1
2
Zero pulse of digital frequency input
X8
C0429 TP1 delay
0
DFIN dead time compensation
TP1 (DI1)
−32767
{1 inc}
32767
C0431 DFIN TP Edge
0
DFIN touch probe TP1 edge
(for touch probe via digital input
X6/DI1 (C0428 = 1))
0
Rising edge TP1
1
Falling edge TP1
2
Rising and falling edge TP1
3
Switched off
C0443 DIS: DIGIN
Signal status of the digital inputs
on X6 after consideration of the
polarity set under C0114.
Only display
0
{1}
255
Bit 0
DIGIN1
X6/DI1
^ 140
Bit 1
DIGIN2
X6/DI2
Bit 2
DIGIN3
X6/DI3
Bit 3
DIGIN4
X6/DI4
Bit 4
DIGIN_safe_standstill
X6/SI2
0: Pulse inhibit is active
1: Pulse inhibit is inactive
^ 70
Bit 5
Free
Bit 6
DIGIN_CInh
X6/SI1
0: Controller is inhibited (CINH)
1: Controller is enabled
^ 70
Bit 7
Free