Appendix, Code table – Lenze ECSCMxxx User Manual
Page 280

Appendix
Code table
l
280
EDBCSXM064 EN 11.0
IMPORTANT
Possible settings
Code
Selection
Lenze/
{Appl.}
Designation
No.
[C0006] Op mode
1
Operating mode of the motor
control
l
If the master pulse (via
MCTRL: C0911 = 0 or DfIn:
C0428 = 0) is used, the
voltage supply has to be
switched off and then on
again when the operating
mode is changed.
l
Otherwise, the master pulses
will not be recognised.
1
Servo PM−SM
Servo control of synchronous
motors
2
Servo ASM
Servo control of asynchronous
motors
C0009 LECOM
address
1
Entry of the device address for
operation via AIF interface X1
1
{1}
99 Communication modules on AIF
interface X1:
l
LECOM−A/B/LI 2102
l
PROFIBUS−DP 2133
C0011 Nmax
3000
Maximum speed
500
{1 rpm}
16000 Reference value for the absolute
and relative setpoint selection
for the acceleration and
deceleration times.
For parameter setting via
interface: greater changes in one
step should only be made when
the controller is inhibited (CINH)!
C0017 FCODE (Qmin)
50
Free code for using speed signals
(Speed signal FCODE_nC17_a)
−16000
{1 rpm}
16000
C0018 fchop
2
Switching frequency
1
4 kHz sin
4 kHz permanent PWM
frequency
2
8/4 kHz sin
8 kHz PWM frequency with
automatic derating to 4 kHz at
high load
C0019 Thresh nact =
0
0
Threshold when actual speed
value (n
act
) = 0 is detected.
(DCTRL_bNActEq0_b)
0
{1 rpm}
16000
C0022 Imax current
à
I
max
limit
0
{0.01 A}
à
Device−dependent list
Max. current can be gathered
from the technical data.
C0023 Imax fld.weak
0
Maximum field weakening
current for synchronous
machines
0
{1 %}
100
C0026
Offset for relative analog signals
(AIN)
1 FCODE(offset)
0,0
−199,99
{0.01 %}
199,99 FCODE_nC26_1_a
2 FCODE(offset)
0,0
FCODE_nC26_2_a