Troubleshooting and fault elimination

Fault analysis

Fault analysis with the history buffer

11

l

265

EDBCSXM064 EN 11.0

Reset fault message

The current fault message can be reset via a TRIP−RESET (e.g. via C0043):

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C0043 Trip reset

0

Reset active fault message
(TRIP−RESET)

^ 278

0

Reset fault message (TRIP−RESET) / no
fault

1

Active fault message

Delete entries in the history buffer

The entries in the history buffer can be deleted via C0167.

ƒ

This function only works when no trouble is active.

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C0167 Reset failmem

0

Delete history buffer (C0168)

^ 264

0

No reaction

1

Delete history buffer