Appendix – Lenze ECSCMxxx User Manual
Page 325

Appendix
Code table
l
325
EDBCSXM064 EN 11.0
IMPORTANT
Possible settings
Code
Selection
Lenze/
{Appl.}
Designation
No.
C3022 DCC−CTRL
enable
1.0
Deceleration time:
Within this time, the manual jog
speed (C3020) is reduced to zero.
^ 165
0.000
{1 s}
999.000
C3030 FolloErrWarn
400000
Following error limit for enabling
a warning
^ 170
0
{1 inc}
2140000000
C3031 FolloErrFail
800000
Following error limit for enabling
a FAIL−QSP
(Quick stop (QSP) is executed.)
^ 170
0
{1 inc}
2140000000
C3032 FollErr1reac
2
First reaction when following
error limit has been reached
^ 170
0
TRIP
1
Message
2
Warning
3
Off
4
FAIL−QSP
C3033 FollErr2reac
4
Second reaction when following
error limit has been reached
^ 170
0
TRIP
1
Message
2
Warning
3
Off
4
FAIL−QSP
C3034 FollowErrDisp
0
Following error
Read only
^ 170
−2147483647
{1 units}
2147483647
C3037 VelModeErr
25.0
Speed deviation for enabling the
response to speed errors (C3038)
0.00
{0.01 %}
100.00
C3038 VelModeErr
Reac
3
Response to speed errors in
"Velocity Mode" (C5000 = 2)
0
TRIP
1
Message
2
Warning
3
Off
4
FAIL−QSP
C3150 Stateword
0
Status word
Read only
^ 134
0
{1 units}
65535