Commissioning
Process data to the axis module (control word Ctrl1 and setpoints)
l
133
EDBCSXM064 EN 11.0
Monitor data selection (C3181)
Depending on the values of the control bits 4 ... 6, the following monitor data can be
transmitted from the drive:
Ctrl1.
Value of the
control
bits 4 ... 6
Monitor data
Meaning
Bit6
Bit5
Bit4
0
0
0
0
Free
0
0
1
1
MCTRL_nPos_a
Axis position 16 bits
0
1
0
2
DINT_TO_INT
(MCTRL_dnPosSet_p)
Following error (
±2
15
increments)
0
1
1
3
MCTRL_nNAct_a
Current speed (n
max
= 2
14
increments)
1
0
0
4
MCTRL_nMAct_a
Current torque (M
max
= 2
14
increments)
1
0
1
5
MCTRL_nlAct_a
Current motor current
(I
max
= 2
14
increments)
1
1
0
6
MCTRL_nDCVolt_a
Current DC−bus voltage
(2
14
[units] = 1000 V)
1
1
1
7
nPosLatchDiff
Difference between actual position and
actual position at touch probe (C6000)