beautypg.com

2 reset fault messages (trip-reset), Reset fault messages (trip−reset), Troubleshooting and fault elimination – Lenze ECSCMxxx User Manual

Page 278

background image

Troubleshooting and fault elimination

Fault messages
Reset fault messages (TRIP−RESET)

11

l

278

EDBCSXM064 EN 11.0

11.3.2

Reset fault messages (TRIP−RESET)

Reaction

Measures to reset the fault message

TRIP/ FAIL−QSP

Note!
As long as a TRIP/FAIL−QSP source is active, the TRIP/FAIL−QSP cannot be reset.

The TRIP/FAIL−QSP can be reset by:

l

Press keypad XT EMZ9371 BC

ð S. Then, press U to re−enable the axis module.

l

Set C0043 = 1.

l

MotionBus (CAN) control word: set C3153/12 (Bit 11) = 1.

l

Set control word C4040/Bit 11 = 1.
(Dependent on the control interface selected in C4010.)

After the TRIP/FAIL−QSP has been reset, the drive remains at standstill.

Message

Danger!
After the fault has been removed, the fault message is removed automatically and the drive
restarts automatically.

Warning

After eliminating the fault, the fault message is reset automatically.