beautypg.com

Appendix – Lenze ECSCMxxx User Manual

Page 294

background image

Appendix

Code table

12

l

294

EDBCSXM064 EN 11.0

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C0196 BRK T rel

0.0

Opening time of the motor
holding brake

^ 105

0.0

{0.1 s}

60.0 During the time set the drive can

generate the torque set under
C0244 against the holding brake.
After the set time has elapsed,
the status "mechanical brake
opened" is reached.

C0199 BuildNumber

Software identification
Only display

C0200 S/W Id

Software identification
Only display

C0201 S/W date

Software release date
Read only

C0202

Service code
Only display

1

Product code 1

...

...

4

Product code 4

C0203 Komm.−No.

x / xxxx / xxxxx

Commission number
Only display

C0204 Serial−No.

Serial number
Read only

C0205 PLC Target ID

Identification key
Only display

C0206 Product. date

Production date
Only display

C0207 DL info 1

Download info 1
Only display

C0208 DL info 2

Download info 2
Only display

C0209 DL info 3

Download info 3
Only display

C0244 BRK M set

0.0

Holding torque of the drive
against the motor holding brake,
with reference to M

max

(C0057).

^ 105

0.00

{0.01 %}

199.99 During the time set in C0196 the

drive generates the set torque
against the holding brake.

C0250 FCODE 1 Bit

0

Freely selectable digital signal
(1 bit)

0

1

C0254 Vp angle CTRL

0.4000

Phase controller gain (V

p

)

0.0000

{ 0.0001}

3.9999

C0300 Service Codes

Only the Lenze service is allowed
to make changes!

...

C0302

C0304 Service Codes

Only the Lenze service is allowed
to make changes!

...

C0310

This manual is related to the following products: