beautypg.com

Commissioning – Lenze ECSCMxxx User Manual

Page 166

background image

Commissioning

Selection of the operating mode
"Manual jog" operating mode

6

l

166

EDBCSXM064 EN 11.0

Operating mode−dependent bits in the control word Ctrl1

ƒ

Hardware limit switch monitoring:

Bit

Name

Value

Response

1

Release limit switch

Only with user software

£1.x (A−SW see nameplate):

0

Limit switch monitoring is active

1

Limit switch monitoring is not active:

l

After a TRIP−RESET, the activated hardware limit switch can be
retracted.

ƒ

Manual jog:
– Ctrl1.Bit13 (JogCW): 1 signal: Manual jog in positive direction.
– Ctrl1.Bit14 (JogCCW): 1 signal: Manual jog in negative direction.
– Both control bits = 1 signal: Stop.

The manual jog parameters set for speed, acceleration, and deceleration apply to manual
jog.

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C4040 Control word

Ctrl1

0

Control word Ctrl1 for C4010 = 3

^ 167

^ 165

0

{1 bit}

1 Here, a drive can also be

traversed without having a
master control (e.g. using GDC).

Bit 0

Toggle

Bit 1

Res.
ECS Motion

£V1.x: deactivate

hardware limit switch monitoring
(release limit switch)

Bit 2

Brake−direct

Bit 3

Quick stop (QSP)

Bit 4

Monitor data selection LSB

Bit 5

Monitor data selection

Bit 6

Monitor data selection MSB

Bit 7

Controller enable

Bit 8

Res.

Bit 9

Controller inhibit (CINH)

Bit 10

TRIP−SET

Bit 11

TRIP−RESET

Bit 12

Operation mode specific (1)

See operating modes (bit 12 =
LSB, bit 14 = MSB):
"IP Mode" (

^ 161)

"Homing Mode" (

^ 164)

"Manual Jog" (

^ 165)

"Velocity Mode" (

^ 167)

Bit 13

Operation mode specific (2)

Bit 14

Operation mode specific (3)

Bit 15

Res.