Commissioning
Selection of the operating mode
"Manual jog" operating mode
l
166
EDBCSXM064 EN 11.0
Operating mode−dependent bits in the control word Ctrl1
ƒ
Hardware limit switch monitoring:
Bit
Name
Value
Response
1
Release limit switch
Only with user software
£1.x (A−SW see nameplate):
0
Limit switch monitoring is active
1
Limit switch monitoring is not active:
l
After a TRIP−RESET, the activated hardware limit switch can be
retracted.
ƒ
Manual jog:
– Ctrl1.Bit13 (JogCW): 1 signal: Manual jog in positive direction.
– Ctrl1.Bit14 (JogCCW): 1 signal: Manual jog in negative direction.
– Both control bits = 1 signal: Stop.
The manual jog parameters set for speed, acceleration, and deceleration apply to manual
jog.
Code
Possible settings
IMPORTANT
No.
Designation
Lenze/
{Appl.}
Selection
C4040 Control word
Ctrl1
0
Control word Ctrl1 for C4010 = 3
^ 167
^ 165
0
{1 bit}
1 Here, a drive can also be
traversed without having a
master control (e.g. using GDC).
Bit 0
Toggle
Bit 1
Res.
ECS Motion
£V1.x: deactivate
hardware limit switch monitoring
(release limit switch)
Bit 2
Brake−direct
Bit 3
Quick stop (QSP)
Bit 4
Monitor data selection LSB
Bit 5
Monitor data selection
Bit 6
Monitor data selection MSB
Bit 7
Controller enable
Bit 8
Res.
Bit 9
Controller inhibit (CINH)
Bit 10
TRIP−SET
Bit 11
TRIP−RESET
Bit 12
Operation mode specific (1)
See operating modes (bit 12 =
LSB, bit 14 = MSB):
"IP Mode" (
^ 161)
"Homing Mode" (
^ 164)
"Manual Jog" (
^ 165)
"Velocity Mode" (
^ 167)
Bit 13
Operation mode specific (2)
Bit 14
Operation mode specific (3)
Bit 15
Res.