Appendix – Lenze ECSCMxxx User Manual
Page 282

Appendix
Code table
l
282
EDBCSXM064 EN 11.0
IMPORTANT
Possible settings
Code
Selection
Lenze/
{Appl.}
Designation
No.
C0052 MCTRL Umot
Actual motor voltage
Read only
0
{1 V}
800
C0053 UG−VOLTAGE
DC−bus voltage
Read only
0
{1 V}
900
C0054 Imot
Actual motor current
Read only
0,0
{0.1 A}
500,0
C0055 Phase current
Motor phase current
Read only
1 iu
0,0
{0.1 A}
500,0 Actual current in U phase
2 iv
Actual current in V phase
3 iw
Actual current in W phase
4 Io
Actual theoretical star−point
current
C0056 MCTRL−MSET2
Torque setpoint on speed
controller output
(MCTRL_nMSetIn_a)
Read only
−100
{1 %}
100
C0057 Max Torque
Maximum possible torque of the
drive configuration
Dependent on C0022, C0081,
C0087, C0088
Read only
0,0
{0.1 Nm}
500,0
C0058 Rotor diff
−90.0
Rotor displacement angle (offset
angle)
Input in case of Lenze motor with
l
resolver: −90°
l
hiperface absolute value
encoder: 0°
Code value is adapted by the
rotor position adjustment
function (C0095).
Only relevant for the operation
of synchronous motors.
^ 180
−180.0
{0.1
_}
179.9
C0059 Mot pole no.
Calculated number of motor pole
pairs
Read only
1
{1}
200
C0060 Rotor pos
Current rotor position; value is
derived from position encoder.
Therefore, it is only valid as rotor
position if the position encoder
settings under C0490 are
identical with the settings of the
speed encoder on the motor
shaft under C0495.
Read only
^ 177
0
{1 inc}
2047 Display with reduced resolution:
1 revolution = 2048 increments