Commissioning – Lenze ECSCMxxx User Manual
Page 115

Commissioning
Setting of the feedback system for position and speed control
TTL/SinCos encoder as position and speed encoder
l
115
EDBCSXM064 EN 11.0
IMPORTANT
Possible settings
Code
Selection
Lenze/
{Appl.}
Designation
No.
[C0095] Rotor pos adj
0
Activation of rotor position
adjustment for automatic
determination of the rotor
displacement angle.
C0058 displays the determined
rotor displacement angle (offset
angle).
^ 180
0
Inactive
1
Active
[C0419] Enc. setup
110
Encoder selection
l
Selection of encoder type
indicated on the nameplate of
the Lenze motor.
l
The encoder data (C0420,
C0421, C0427) is set
automatically in accordance
with the selection.
^ 113
^ 121
0
Common
110
IT512−5V
Incremental encoder with TTL
level
111
IT1024−5V
112
IT2048−5V
113
IT4096−5V
210
IS512−5V
SinCos encoder
211
IS1024−5V
212
IS2048−5V
213
IS4096−5V
307
AS64−8V
SinCos absolute value encoder
with Hiperface® interface
(single−turn)
Selections 307, 308, 309 are only
possible with operating system
7.0 or higher.
308
AS128−8V
309
AS256−8V
310
AS512−8V
311
AS1024−8V
407
AM64−8V
SinCos absolute value encoder
with Hiperface® interface
(multi−turn)
Selections 407, 408, 409 are only
possible with operating system
7.0 or higher.
408
AM128−8V
409
AM256−8V
410
AM512−8V
411
AM1024−8V
[C0420] Encoder const.
512
Number of increments of the
encoder
^ 113
^ 121
1
{1 inc/rev}
8192 Sets C0419 = 0 ("common") if the
value is altered.
[C0421] Encoder volt
0
Encoder voltage
^ 113
^ 121
0
5.0 V
Sets C0419 = 0 ("common") if the
value is altered.
1
5.6 V
2
6.3 V
3
6.9 V
4
7.5 V
5
8.1 V