Monitoring functions, Overview of monitoring functions – Lenze ECSCMxxx User Manual
Page 224

Monitoring
functions
Overview of monitoring functions
9
l
224
EDBCSXM064
EN 11.0
Possible fault responses
l Lenze setting
ü Can be set
Monitoring
Off
Fail−QSP
Warning
Message
TRIP
Code
Source
Description
Fault message
0072
PR1
Check sum error in parameter set 1
Internal
l
0074
PEr
Program error
Internal
l
0075
PR0
Error in the parameter sets
Internal
l
0079
PI
Error during parameter initialisation
Internal
l
0080
PR6
l
For ECSxS/P/M:Internal fault
l
For ECSxA: Too many user codes
Internal
l
Application−specific fault messages
x400
Pos HW End Positive hardware limit switch has bee approached.
C3175
ь
ь
ь
l
x401
Neg HW
End
Negative hardware limit switch has been approached.
C3175
ь
ь
ь
l
x404
Follow Err 1 Warning against exceeding the following error limit (C3030).
C3032
ь
ь
l
ь
ь
x405
Follow Err 2 Following error limit (C3031) has been exceeded.
C3033
ь
ь
ь
l
ü
x406
Home Pos
Err
Home position is unknown.
C3170
ь
ь
ь
ь
l
x407
Toggle Bit
Err
Toggle bit error
C3160
ь
ь
ь
l
ü
3408
External
QSP
Externally enabled quick stop (QSP) via X6/DI1
(A reset of the fault message is required.)
l
x410
VelModeErr Speed error in "Velocity Mode" (C5000 = 2)
C3038
ь
ь
ь
ь
l
x: 0 = TRIP, 1 = message, 2 = warning, 3 = FAIL−QSP
1)
Adjustable in the DDS under Project
W Exceptional handling
2)
For ECSxA... only