beautypg.com

Monitoring functions, Overview of monitoring functions – Lenze ECSCMxxx User Manual

Page 224

background image

Monitoring

functions

Overview of monitoring functions

9

l

224

EDBCSXM064

EN 11.0

Possible fault responses

l Lenze setting

ü Can be set

Monitoring

Off

Fail−QSP

Warning

Message

TRIP

Code

Source

Description

Fault message

0072

PR1

Check sum error in parameter set 1

Internal

l

0074

PEr

Program error

Internal

l

0075

PR0

Error in the parameter sets

Internal

l

0079

PI

Error during parameter initialisation

Internal

l

0080

PR6

l

For ECSxS/P/M:Internal fault

l

For ECSxA: Too many user codes

Internal

l

Application−specific fault messages

x400

Pos HW End Positive hardware limit switch has bee approached.

C3175

ь

ь

ь

l

x401

Neg HW
End

Negative hardware limit switch has been approached.

C3175

ь

ь

ь

l

x404

Follow Err 1 Warning against exceeding the following error limit (C3030).

C3032

ь

ь

l

ь

ь

x405

Follow Err 2 Following error limit (C3031) has been exceeded.

C3033

ь

ь

ь

l

ü

x406

Home Pos
Err

Home position is unknown.

C3170

ь

ь

ь

ь

l

x407

Toggle Bit
Err

Toggle bit error

C3160

ь

ь

ь

l

ü

3408

External
QSP

Externally enabled quick stop (QSP) via X6/DI1
(A reset of the fault message is required.)

l

x410

VelModeErr Speed error in "Velocity Mode" (C5000 = 2)

C3038

ь

ь

ь

ь

l

x: 0 = TRIP, 1 = message, 2 = warning, 3 = FAIL−QSP

1)

Adjustable in the DDS under Project

W Exceptional handling

2)

For ECSxA... only

This manual is related to the following products: