Mechanical installation

Mounting in cold−plate design

Mounting steps

4

l

47

EDBCSXM064 EN 11.0

4.4.2

Mounting steps

А

Б

В

ECSXA030

Fig. 4−6

Mounting for "cold−plate design"

Proceed as follows to mount the axis module:

1. Prepare the fixing holes on the mounting plate.

– Use a drilling jig for this purpose.

2. Clean and degrease the contact area of collective cooler and heatsink of the

axis module (e.g. with methylated spirit).

3. Screw the support onto the collective cooler.

4. Insert the axis module from above

 into the support ‚ and fasten the two stud

bolts with 3.5 ... 4.5 Nm

ƒ.

)

Note!

Penetration depth of the screws into the collective cooler: approx. 15 mm!

I

Tip!

The heat transfer resistance is reduced if − following step 2. −

ƒ

a thin layer of heat conducting paste is applied to the contact surface or

ƒ

heat conducting foil is used.