beautypg.com

16 following error monitoring (c3030, c3031), Commissioning – Lenze ECSCMxxx User Manual

Page 170

background image

Commissioning

Following error monitoring (C3030, C3031)

6

l

170

EDBCSXM064 EN 11.0

6.16

Following error monitoring (C3030, C3031)

Following errors are monitored in all motion states of the drive.

To configure the monitoring of following errors use C3030/C3031 (following error limits)
and C3032/C3033 (reactions to following errors) in the GDC parameter menu under
Motion

W Machine parameter.

v [m/s]

t [s]



‚

ƒ

A

B

ECSXA416

Fig. 6−31

Following error

0

Setpoint speed profile (the area below the curve corresponds to the path)

1

Profile travelled



The drive decelerates, a difference between set position and actual position arises.

‚

Following error tolerance is exceeded.

ƒ

End of the set profile

If the difference between set position and actual position is higher than the following error
limit, the higher−level control must activate a reaction according to the set error class.

ƒ

When the first following error limit in C3030 is reached, the first error reaction set in
C3032 is activated.

ƒ

When the first following error limit in C3030 is reached, the second error reaction
set in C3033 is activated.

)

Note!

For correct monitoring of following errors set:

ƒ

Limit value in C3031 > limit value in C3030 and

ƒ

error reaction in C3033 stronger than error reaction in C3032

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C3030 FolloErrWarn

400000

Following error limit for enabling
a warning

^ 170

0

{1 inc}

2140000000

C3031 FolloErrFail

800000

Following error limit for enabling
a FAIL−QSP
(Quick stop (QSP) is executed.)

^ 170

0

{1 inc}

2140000000

This manual is related to the following products: