Page 164

Commissioning
Selection of the operating mode
"Homing" operating mode
l
164
EDBCSXM064 EN 11.0
6.14.2
"Homing" operating mode
)
Note!
ƒ
No homing with absolute value encoders.
ƒ
Use C0098 to set another position than the one transmitted by the absolute
value encoder.
Settings
ƒ
Select "Homing Mode": C5000 = 6
– The code C5000 (4C77h) is written via parameter channel (SDO) (
^ 345).
ƒ
Selection confirmation: C5001 = 6
– The selection of "homing mode" is confirmed.
– The code C5001 (4C76h) must be read out via parameter channel (SDO).
ƒ
Start homing: Ctrl1.Bit12 = 1 (TRUE)
Operating mode−dependent bits in the control word Ctrl1
Bit
Name
Value
Response
1
Release limit switch
Only with user software
£1.x (A−SW see nameplate):
0
Limit switch monitoring is active
1
Limit switch monitoring is not active:
l
After a TRIP−RESET, the activated hardware limit switch can be
retracted.
12
Activate "Homing
Mode"
0
Homing is not executed.
0
à 1
Start of homing
1
Homing is being executed.
1
à 0
Homing is interrupted or completed.
Operating mode−dependent bits in the status word
Bit
Name
Value
Response
1
Homing is active
0
"Homing mode" is not active
1
Homing is started by setting the control bit 12 = 1.
2
Reference known
0
Homing is being executed or has been aborted.
1
Homing is completed.
à Reference is known.
3
Reference error
0
No error during homing
1
Error during homing
àFunction abort
4
Reference switch
0
Reference switch is not active
1
Reference switch is active