beautypg.com

Commissioning – Lenze ECSCMxxx User Manual

Page 161

background image

Commissioning

Selection of the operating mode

Operating mode "Interpolated Position Mode" (IP−Mode)

6

l

161

EDBCSXM064 EN 11.0

6.14.1

Operating mode "Interpolated Position Mode" (IP−Mode)

The "IP mode"enables a travel according to setpoint selection.

Settings

ƒ

Select "IP mode": C5000 = 7
– The code C5000 (4C77h) is written via parameter data channel (SDO,

^ 345).

ƒ

Selection confirmation: C5001 = 7
– Code C5001 (4C76h) can be read out via parameter data channel (SDO) in order to

query whether the operating mode in the drive has been changed already.

– Write/read access via SDO may take typically 30 ... 50 ms.

ƒ

Enable "IP mode": Ctrl1.Bit12 = 1 (TRUE)
– The travel according to setpoint selection has not been started yet due to

changeover to "IP mode". The "IP mode" must be enabled by control bit
(Ctrl1.Bit12 = 1).

Operating mode−dependent bits in the control word Ctrl1

Bit

Name

Value

Response

1

Release limit switch

Only with user software

£1.x (A−SW see nameplate):

0

Limit switch monitoring is active

1

Limit switch monitoring is not active:
After a TRIP−RESET, the activated hardware limit switch can be
retracted.

12

Enable IP mode

0

Without function

1

Enable IP mode so that the drive follows the cyclically defined
setpoints.

13

Activate Pos_Latch

0

Without function

1

Touch probe storage is activated.
The TP position is detected with the next selected touch probe edge
(

^ 162).

)

Note!

The external setpoint can only be read if the "IP mode" has been enabled
(Ctrl1.Bit12 = 1). Otherwise, the drive must control the motor with the internal
setpoint.

Operating mode−dependent bits in the status word

Bit

Name

Value

Response

1

Enable IP mode

0

IP mode is not enabled

1

Enable IP mode

2

Evaluate Pos_Latch

0

No touch probe signal occurred

1

The active touch probe edge has completed the position detection.

3

Pos_Latch error

0

No error during position detection

1

Error during position detection

à Function abort

4

Touch probe sensor

0

No touch probe

1

Touch probe sensor is active

This manual is related to the following products: