Load configuration, Run configuration, Load configuration run configuration – Kinze Ag Leader Integra User Manual
Page 329: Onfiguration
![background image](/manuals/564399/329/background.png)
313
H
ARVEST
H
ARVEST
M
ONITORING
/M
APPING
When performing a Harvest operation, the AutoSwath feature includes sensitivity levels, which
compensate for varying levels of GPS accuracy.
Press: Home button > Setup (wrench) button > Configuration (tractor) button > Configuration tab > your
specific configuration > Setup (wrench) button >Automatic Swath Control button
The Automatic Swath Control screen appears.
If swath adjustments are performing inaccurately, adjust the sensitivity accordingly. Sensitivity 3 is the
default setting. Other settings include:
• Sensitivity 5
Use with RTK or DGPS sub-meter, terrain compensated GPS.
• Sensitivity 4
Use with RTK or DGPS sub-meter GPS. Terrain compensation recommended.
• Sensitivity 3
Use with sub-meter accurate GPS.
• Sensitivity 2
Use with 1+ meter accurate GPS.
• Sensitivity 1
Swath sections are all on or all off. Use with 1+ meter accurate GPS.
L
OAD
C
ONFIGURATION
Press: Select Event button.
Select a Season, Grower, Farm, and
Field on the Management Selection
screen.
R
UN
C
ONFIGURATION
Once a configuration has been completed, the Map View button appears at the bottom of the
Home screen. Press the Map View button to see the Map screen.
Configuration
Select Your Specific
Configuration
Automatic Swath Control
Select Event