Liquid application diagnostics, Iagnostics, Pplication – Kinze Ag Leader Integra User Manual
Page 249: Iquid
![background image](/manuals/564399/249/background.png)
233
A
PPLICATION
L
IQUID
R
ATE
C
ONTROL
3. Select Data From Shape File
Select the column that contains the product
recommendation rate. The list on the right side of the
dialog shows sample data from the selected column.
4. Select Units
Select the controlling units for product application.
5. Default Rate Setting
The system assigns a default rate. Use the on-screen
keypad to edit the value if desired.
CAUTION: Selection of the wrong data column or unit will result in misapplication of product.
Note: The only time the default rate is used by the system during product application is if the Rate Outside of
Field selection is set to " Rx default". This setting is located in the equipment configuration settings portion of
configuration setup. If the Rate Outside of Field selection is set to "Rx default", the default target rate will be
used when the vehicle exits the area covered in the prescription map.
L
IQUID
A
PPLICATION
D
IAGNOSTICS
To go to the Liquid Diagnostics screen, press on the Device Information button. At the
Devices screen, highlight the item marked DC Liquid then press the Diagnostics button.
The Liquid Diagnostics screen includes
the Active Controller Name and the
Serial Number of the module. Other
information provided includes the Main
Pressure, Agitation Pressure, and
Auxiliary Pressure. These raw sensor
readings are shown in kilopascals (kPa).
Note: If you selected PWM as the Control Valve then the current PWM Duty Cycle is shown as a percentage
number, in the PWM Duty Cycle (%) item on the Liquid Diagnostic screen.
• Flow Meter Signal Frequency (Hz)
View the frequency generated by the flow meter during product application. Use this to make sure the flow
meter is providing continuous feedback.
Select Prescription
Column
NH3
Units
gallons
Default Rate
50
Product: NH3
140
135
130
125
120
Column Preview
Controller Name
Serial Number
Main Pressure (kPa)
Agitation Pressure (kPa)
Auxiliary Pressure (kPa)
PWM Duty Cycle (%)
Flow Meter Signal Frequency (Hz)
Fow Meter Pulse Count
DirectLiquid
2003750001
738
662
655
2.55
0
0
Liquid Diagnostics