Note: The settings, provided below, should be a good starting point for controller settings. However, always
take the time to calibrate the seed meters, check for proper seed placement in the field, and make system
setting adjustments as needed. Do not rely solely upon the appearance of the On-Screen map. The on screen
map will not show gaps and overlaps caused by incorrect GPS Offsets or AutoSwath Look-Ahead settings.
Planter brand
Control V
alve Configuration
PWM Frequency
PWM Gain
Zero Flow Of
fset
Gear Ratio
Pulses/Rev
.
John Deere Planters
PWM
175
110
40
2.374 (chain)
2.417
(ProShaft)
360
White Planters
PWM
200
90
30
5.5
360
Case IH Planters
PWM
100
90
40
6.803
360