Troubleshooting, Alarms on kinze planter monitor, Roubleshooting – Kinze Ag Leader Integra User Manual
Page 229: Larms on, Kinze p, Lanting, Lanter, Onitor
![background image](/manuals/564399/229/background.png)
213
P
LANTING
KINZE P
LANTER
M
ONITOR
M
ODULE
• Shaft Speed
The speed of the planter drive shafts, in
RPM.
• Tank Weight
The weight of seed in each tank of the ASD
system.
• Tank Area Left
The number of acres (hectares) that can be
planted with the amount of seed remaining
in the tanks of the ASD system.
• ASD Tank Pressure
The air pressure level for the Air Seed
Delivery (ASD) system.
• EdgeVac Level
Measure of seed meter vacuum. This
measurement, shown in inches of water, is displayed for each vacuum fan.
• Pneumatic Down Pressure
Measure of down force the air bag places on the row unit.
• Magnetic Pickup Speed
Speed registered according to the magnetic pickup.
T
ROUBLESHOOTING
A
LARMS ON
KINZE P
LANTER
M
ONITOR
When the Active Alarms window is shown, use the scroll bar on the right hand side to locate the row
units where the alarm is occurring. Acknowledge the alarm by pressing
. After dismissing the
alarm, you may continue planting, however, the alarm will continue showing in the title bar. You may also
review the alarm information underneath the CAN device list shown underneath CAN Diagnostics.
The table below describes various alarms that may occur at system startup. The following pages
describe errors that could occur during field operations.
Error Message: “Sensors calibrating wait for calibration”
Possible Cause: PMM startup
Solution: Wait for Planter Monitor Module (PMM) to finish before beginning operation.
Error Message: “(Row #) sensor not detected”.
Possible Cause: Population sensor did not begin communicating with the PMM.
Solution: Acknowledge the error by pressing OK. Check the LED on the sensor to see if it is
working properly. If it has failed, then replace the sensor. Refer to the KINZE Planter
Operator’s manual for further instructions.
Error Message: “Clean or replace sensor (Row #) as necessary”.
Possible Cause: Population sensor dirty.
Solution: Press OK to dismiss the error. Then clean the sensor and restart the system.
34000 sds/ac
147 ac
74 ac
240 lb
117 lb
250 lb
7 in
20.0 in
5 mph
Spacing: 8 in
5.0
mph
38.4
ac
Outer Left
Inner Left
Inner Right
60 rpm
60 rpm
60 rpm
C1291
59 rpm
Population: 26100 sds/ac
100 rpm
100 rpm
ASD
Left
Right
Weight
Area Left
ASD Tank Pressure
Edge Vac Left
Edge Vac Right
SDS Left
SDS Right
Magnetic Pickup
High
Low
20.0 in
250 lb
Gauge Wheel:
Down Force:
CSX56A11
CSZ1927
52 rpm
53 rpm
36000 sds/ac
38000 sds/ac
38000
34000
Population
36000
Down Force
60 %
80 %
100 %
120 %
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
23
24
22