Kinze Ag Leader Integra User Manual
Page 292

276
Firmware Version 5.2
8. Enter Controller Name
Controller name defaults to DirectSpreader. Press
to accept, or press
to enter a new
name if desired. Press
to continue.
9. Container Setup (Equipment Setup Wizard:Container screen)
Press the desired channel button to enable or disable controller channel. A check mark will appear in the
box when the container is ready to be configured.
10. Assign Container Name
Container names default to “Bin 1-5”depending on which granular control module is being used. Press
to enter a new name if desired.
11. Assign Container Capacity
Press
to enter the container capacity. Press
to accept.
12. Enter Container Units
Use the drop-down menu to select the container units.
Once container has been configured press
to continue.
Note:
Follow steps 9-12 for each control channel.
13. Enter Application Point Offset
Press
to enter distance from hitch to application point (front to back). Press
to accept
value on offset screen. Press
to accept value for the application point.
Note:
If setting up a Self-Propelled Applicator, enter the distance from rear axle to application point.
Use drop-down menu to select distance Behind or In Front.
Note:
At this point additional functionality can be added to the implement. If no additional
functionality is being added, press
to continue.
14. Add Additional Devices (optional)
Press
to add boom sensor functionality.
• Press
to enter sensing width (defaults to implement width, change only if necessary).
• Use
/
to enter number of sensors.
• Press Swath Offsets button to enter offsets. System can not be configured with sensors and application
point on opposite sides of the hitch.
Press
to continue.
Self-Propeller Spreader