HP 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem User Manual
Page 90
Virtual Connect networks 90
Field name
Description
within VCM.
Labels
A network can have up to 16 user-defined labels to group and identify the
network within VCM.
To enable Smart Link, edit the network settings after the network is
created. The checkbox is not available until an uplink is added to the
network.
Private Network ("
" on
Select whether to designate (checked) or not designate (unchecked) this
network as a private network.
Enable VLAN Tunneling ("
" on page
Select whether to enable (checked) or disable (unchecked) VLAN
Tunneling. If enabled, VLAN tags for this network are passed through the
domain without any modification. If disabled, all tagged frames are
discarded. If this network is assigned to a server profile or associated with
a shared uplink set, this option cannot be modified.
External Uplink Ports
Use Shared Uplink Set
Enables the selection of a shared uplink set to be used as the uplink port
for this network. For more information, see “Shared uplink sets and VLAN
)."
Port
Network port locations (enclosure, bay, and port numbers)
Port Role
Applicable when Failover Connection Mode is selected. The port can be
designated as Primary or Secondary.
Port Status
Shows the link status, link speed, and connectivity of the port. If the port is
unlinked and no connectivity exists, the cause is displayed. For more
information about possible causes, see "Port status conditions (on page
)."
Connector Type
Displays the type of connector on the port; for example, RJ-45
Connected to
If the port is connected to a switch that supports LLDP, the switch MAC
address and switch port appear. A link is provided to obtain more
information about the far-end switch port.
PID
When selected, sets/clears the port identifier color as blue on the VC-Enet
module to aid in the location of the specific uplink. The PID status for the
overall network also appears.
Speed/Duplex
Pull-down menu to specify the speed and duplex (where applicable) of the
uplink port. Half-duplex operations are not supported by the VC-Enet
module.
Network Access Groups
Displays the Network Access Groups that include this network.
The following table describes the available actions in the Define Ethernet Network Screen. Clicking another
link in the pull-down menu or left navigation tree causes current edits that have not been applied to be lost.
Task
Action
Define network color
Select a color from the Color pull-down menu.
Define network label
Type a label in the Labels field, and then press Enter. A network can have
up to 16 labels. Labels cannot contain spaces and are limited to 24
characters.
Enable Smart Link on the network being
defined
Select the Smart Link checkbox. The checkbox is not available until an
uplink is added to the network.
Designate the network as a private
network
Select the Private Network checkbox.
Enable VLAN tunneling
Select the Enable VLAN Tunneling checkbox.
Set a custom value for preferred link
Select the Advanced Network Settings checkbox. For more information,
- Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem