beautypg.com

Interconnect bay overall status icon definitions – HP 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem User Manual

Page 197

background image

Virtual Connect modules 197

Column

Description

Port Speed Setting

Speed setting of the uplink port

Connector Status

Status of the uplink port

Connected To

WWN of the principal FC switch to which the VC-FC uplink port is connected

The following table describes the rows within the Server Port Information table in the Bay Summary Screen.

Click Less < to display only the Port, Server Blade, SAN Fabric, Connected To, and Profile columns. Click

More > to display all columns.

Column

Description

HBA Port

HBA port number

Server Blade

Server blade bay location

SAN Fabric

Name of the SAN Fabric connected to this port
To edit the SAN Fabric, click the SAN Fabric in the left navigation tree.

Connected To

WWN address of the device that this port is connected to on the other end

Profile

Server profile with connections to this port

HBA Port Speed

Speed setting of the HBA port

HBA Port Status

Status of the HBA port

HBA WWPN

Either the World Wide Port Name assigned to the port or the Server Factory
Default, if not assigning WWNs using Virtual Connect

Interconnect Bay Overall Status icon definitions

Icon

Operational state Meaning

Corrective action

OK

Device is fully operational.

None

Unknown

Device operational state cannot be

determined.

Check Onboard Administrator

communication.

(blue)

Initializing

Device is initializing.

Wait until initialization is complete.
(This icon should only be seen at

startup.)

(yellow)

Degraded

Device is partially operational, but

capability is lost.

Check and correct the Onboard

Administrator error condition.

(orange)

Misconfigured

Device has a configuration error.

Correct the Virtual Connect Manager

configuration attributes.

(orange)

Incompatible

Device does not match the

configuration.

Remove the incorrect hardware. Insert

the correct module.

(orange)

No communication

Cannot communicate with the

device.

Check the physical connections and IP

address.

Missing

Device is configured but not

accessible.

Insert the correct hardware module.

Failed

Device is not operational because

of an error.

Reset the device or application, or

replace the device.