Bandwidth assignment – HP 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem User Manual
Page 131
Virtual Connect server profiles 131
If FCoE connections are configured, VCM sets the FCoE personality to the PF. If FC boot parameters are
configured, VC Manager writes these to the NIC and sets the boot order as it does in the case of iSCSI boot
parameters.
In the first example, a profile with eight Ethernet and two FCoE connections is assigned to a server with a
1-Gb LOM and a dual-port 57711 Broadcom MEZ card in MEZ1 and a CNA in MEZ2. The results of the
mapping algorithm are shown in Table 2. Each 1-Gb LOM port only has one connection assigned.
Device
Port
Type
VC Connections Assigned
LOM
1
1 Gb
Enet 1
2
1 Gb
Enet 2
MEZ1
1
Broadcom 57711
Enet 3, Enet 7
2
Broadcom 57711
Enet 4, Enet 8
MEZ2
1
NC551m
Enet 5, FCoE 1
2
NC551m
Enet 6, FCoE 2
In the second example, a profile with two iSCSI, ten Ethernet, and two FCoE connections is assigned to a
server with a Flex-10 LOM and NC551m dual-port MEZZ card in MEZZ1 and MEZZ2. The results of the
mapping algorithm are shown in the following table.
Device
Port
Type
VC Connections Assigned
LOM
1
Broadcom 57711
FlexFabric
Enet 1, Enet 7
2
Broadcom 57711
FlexFabric
Enet 2, Enet 8
MEZ1
1
NC551m
Enet 3, FCoE 1, Enet 9
2
NC551m
Enet 4, FCoE 2, Enet 10
MEZ2
1
NC551m
Enet 5, iSCSI 1
2
NC551m
Enet 6, iSCSI 2
The third example is similar to the second except that the LOM is the NC551i. The example compares ten
Ethernet, one iSCSI, and four FCoE connections. The second PF on MEZZ2:Port 2 has to be enumerated as
iSCSI since the corresponding PF on port 1 is iSCSI. But, since there is only one iSCSI connection defined in
the Profile, the second PF on MEZZ2:Port 2 is disabled.
Device
Port
Type
VC Connections Assigned
LOM
1
NC551i
Enet 1, FCoE 1, Enet 7
2
NC551i
Enet 2, FCoE 2, Enet 8
MEZ1
1
NC551m
Enet 3, FCoE 3, Enet 9
2
NC551m
Enet 4, FCoE 4, Enet 10
MEZ2
1
NC551m
Enet 5, iSCSI 1
2
NC551m
Enet 6, iSCSI (PF disabled)
Bandwidth assignment
In Flex-10 environments, four FlexNICs must share a single 10Gb link. Each FlexNIC is allocated a portion
of that 10Gb link's bandwidth. The bandwidth assigned to the four FlexNICs in a single physical port cannot
exceed 10Gb, but the requested bandwidth settings you specified in the profile might exceed 10Gb.
- Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem