HP 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem User Manual
Page 129
Virtual Connect server profiles 129
Use the iSCSI offload feature to offload iSCSI protocol processing from the OS to the NIC. In addition to
offloading TCP/IP protocol processing, it also offloads iSCSI protocol processing.
The following items are required for iSCSI offload and boot:
•
VC 3.10 or higher firmware
•
HP VC FlexFabric 10Gb/24-port Module—supports iSCSI, and supports FCoE connections to server
bays
•
HP VC Flex-10 10Gb Ethernet Module—supports iSCSI
•
The latest BIOS on a supported server. See the Virtual Connect QuickSpecs on the Installing tab of the
HP BladeSystem Technical Resources website
•
NIC requirements:
o
HP NC551i Dual-Port FlexFabric Converged Network Adapter
o
HP NC551m Dual-Port FlexFabric Converged Network Adapter
o
HP NC553i 10Gb 2-port FlexFabric Converged Network Adapter
o
HP NC553m 10Gb 2-port FlexFabric Converged Network Adapter
•
One Command OS tool
•
be2iSCSI driver
•
be2iSCSI Driver Update Disk for iSCSI boot installs
•
iSCSI target
•
DHCP server (optional)
The following features are supported:
•
Full Flex-10 support
•
Multi-personality—all Ethernet, Ethernet/iSCSI, or Ethernet/FCoE
•
Four physical functions per port
•
Up to 128 iSCSI targets per iSCSI function
•
Primary/Secondary iSCSI boot path per adapter
•
The iSCSI function on the adapter appears to the OS as a standard SCSI device.
•
With the new iSCSI driver, no network driver is needed
•
Does not use software iSCSI initiator from the OS
It is not possible to enable both SAN boot (FC or FCoE) and iSCSI boot in a server profile at the same time.
The priority is given to the first connection that is enabled, which might be FC/FCoE or iSCSI.
Be sure that your Ethernet adapter, operating system, and device drivers support iSCSI boot.
An iSCSI connection cannot be assigned to multiple networks.
The following steps provide an overview of the procedure to enable iSCSI boot:
1.
Create iSCSI connections on the Profile page.
2.
Enable boot on those connections by choosing Primary and optionally Secondary under Boot Setting.
3.
Enter all iSCSI boot parameters for the primary and secondary connections. It is possible (and likely)
that most or all the parameters associated with primary and secondary connections are the same.
4.
Apply the Profile.
- Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem