Virtual Connect domains 41
•
The event severity is Info (informational).
•
The event message is VCM user logout : [email protected].
The following table describes the Virtual Connect managed objects that are capable of generating System
Log events, along with the corresponding event ID ranges.
VC object name
Object short name
Event ranges
Domain
VCD
1000 – 1999
Enclosure
ENC
2000 – 2999
Ethernet Modules
ENET
3000 – 3999
FC Modules
FC
4000 – 4999
Servers
SVR
5000 – 5999
Profiles
PRO
6000 – 6999
Ethernet Network
NET
7000 – 7999
FC Fabric
FAB
8000 – 8999
Unknown Module
UNK
9000 – 9999
Network Access Groups NAG
12000 – 12999
The event severity reflects the functional state of the Virtual Connect object. The event severities include:
•
SEVERITY_INFO–A low-level condition for out-of-service equipment, system login/logout, and other
non-service affecting information
•
SEVERITY_WARNING–A threshold was reached or an error condition is imminent
•
SEVERITY_MINOR–An error condition that has no service impact
•
SEVERITY_MAJOR–A critical event that impairs service and requires immediate action (substantially
diminished capacity or a service outage)
•
SEVERITY_CRITICAL–A critical event that severely impairs service and requires immediate action
(substantially diminished capacity or a service outage)
- Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem