HP 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem User Manual
Page 161
Virtual Connect server profiles 161
Column name
Description
Allocated Bandwidth
Allocated bandwidth of the port. See "Bandwidth assignment (on page
)."
Boot Setting
Enables or disables offload or boot on the network connection. Valid values
are DISABLED, PRIMARY, (SECONDARY), and USE-BIOS. For more
information, see "Creating iSCSI connections (on page
)." After selecting
an option, you must click outside the grid to complete the selection. This is the
same procedure that is followed when selecting a fabric or network for an FC
or Ethernet connection, respectively. Once the Boot Setting column has been
completed, you can then edit the Target Port Name and LUN.
MAC
The MAC address assigned to the port, or "Server Factory Default" if not
using VC-assigned MAC addresses
Mapping
Server hardware mapping assignment. See "iSCSI and FCoE port
assignments (on page
)."
Action
Delete a connection. Connections can be removed starting with the last
connection in the list.
FC HBA Connections
Port
Relative order of the Fibre Channel port on the server receiving the profile
Connected to
Bay number of the VC-FC module to which the port is connected
FC SAN Name
Name of the SAN fabric to which the port is connected, or Unassigned
Status
Status of the Fibre Channel module
Port speed
Speed of the VC-FC module port connected to the port
WWPN
The World Wide Port Name assigned to the port, or "Server Factory Default"
if not using VC-assigned MAC addresses
Action
Delete a connection. Connections can be removed starting with the last
connection in the list.
FCoE HBA Connections
Port
Relative order of the FCoE port on the server receiving the profile
Connected to
Bay number of the VC module to which the port is connected
FC SAN Name
Name of the SAN fabric to which the port is connected, or Unassigned
Status
Status of the VC module
Port Speed
Speed of the VC module port connected to the port
Allocated Bandwidth
Allocated bandwidth of the port. See "Bandwidth assignment (on page
)."
WWPN
The World Wide Port Name assigned to the port, or "Server Factory Default"
if not using VC-assigned MAC addresses
MAC
The MAC address assigned to the port, or "Server Factory Default" if not
using VC-assigned MAC addresses
Mapped
Server hardware mapping assignment. See "iSCSI and FCoE port
assignments (on page
)."
Action
Delete a connection. Connections can be removed starting with the last
connection in the list.
* Only Flex-10 NICs and FlexFabric NICs connected to Flex-10 modules and FlexFabric modules are able to
set the transmit bandwidth allocation. Other parts are restricted to the actual physical speed (1Gb).
The following table describes the available actions in the Edit Server Profile screen. Clicking another link in
the pull-down menu or left navigation tree causes current edits that have not been applied to be lost.
- Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem