HP 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem User Manual
Page 200
Virtual Connect modules 200
in physical Bay 1, Bay 1 in VC Manager is displayed as COVERED, and Bays 1A and 1B display the
appropriate double-dense server blade information.
If the VC domain is configured for double-dense server mode, and a profile is assigned to an empty
double-dense server bay, then a hot-plug installation of a single-dense server into the corresponding
single-dense server bay results in the profile not being activated because the profile is not assigned to the
single-dense server bay. To recover the profile, assign the profile to the single-dense server bay.
This manual is related to the following products:
- Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem