HP 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem User Manual
Page 38
Virtual Connect domains 38
The VC-FC SNMP settings apply to all VC-FC modules in the VC domain.
The following table describes the fields within the SNMP Configuration screen.
Field name
Description
Enable SNMP
Select to enable SNMP.
Enable SMI-S
Select to enable SMI-S
System Contact
Specify a contact name for this system when SNMP is enabled. The maximum
length is 20 characters.
Read Community
Controls SNMP read access when SNMP is enabled. The default value is "public".
The read community string must always be set when SNMP is enabled. The
maximum length is 24 characters.
SNMP Trap Destinations
SNMP trap destination table
Destination
User-designated name for the trap destination. The Destination name must be
unique.
IP Address
IPv4 address for the trap destination. DNS name is not supported.
Community String
The Community String acts like a password for a given trap destination. The
trap-receiving application can use the community string to filter the incoming traps.
Default: public
Format
Format of the new trap (SNMPv1)
Action
Perform edit and delete operations
The following table describes the available actions in the SNMP Configuration screen. Clicking another link
in the pull-down menu or left navigation tree causes current edits that have not been applied to be lost.
- Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem