beautypg.com

Interconnect bay summary screen (vc-fc module) – HP 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem User Manual

Page 195

background image

Virtual Connect modules 195

Pluggable Module Information

Description

vendor-part-number

Manufacturer part number (not an HP part number). This is defined in

SFF-8472 in the Vendor OUI [Address A0h, Bytes 40-55] field.

vendor-revision

Manufacturer part revision number (not an HP part revision number). This

is defined in SFF-8472 in the Vendor OUI [Address A0h, Bytes 56-59]
field.

Interconnect Bay Summary screen (VC-FC module)

This screen provides a summary of the interconnect module status and port information. To remove a module,
see "Interconnect module removal and replacement (on page

209

)."

The following table describes the rows within the Interconnect Bay Status (VC-FC Module) table in the Bay

Summary screen.

Row

Description

Overall Status

Represents the worst condition of OA Reported Status, VC Status, and OA
Communication Status

Hardware Status

Component health status from the Onboard Administrator

VC Status

Component health status from the Virtual Connect Manager

OA Communication Status

Current Virtual Connect Manager to Onboard Administrator communication
state

Rack Name

Name of the enclosure rack (assigned through the Onboard Administrator)

Enclosure Name

Name of the enclosure (assigned through the Onboard Administrator)