HP 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem User Manual
Page 186
Virtual Connect modules 186
Row
Description
Enclosure Name
Name of the enclosure (assigned through the Onboard Administrator)
Bay
Number of the bay being summarized on this screen
Module Host Name
Includes controls that enable you to set a custom host name for the module and
reset the module
Power Status/Control
Power state of the device
The following table describes the rows within the Interconnect Bay Information table in the Bay Summary
screen.
Row
Description
Part Number
The part number to be used when ordering an additional module of this type
Product Name
The common descriptive name of the module
Serial Number
The unique serial number of the module
Dip Switch Setting
The current physical setting of the system maintenance switches in a
hexadecimal format, where the least significant four bits of the value
correspond to the four switches and a bit value of 1 indicates the switch is in
the "on" position.
Spare Part Number
The part number to be used when ordering a replacement module of this type
Manufacturer
The manufacturer of the module
Firmware Rev
The current firmware revision of the module
The following table describes the columns within the Uplink Port Information table in the Bay Summary
screen.
Column
Description
Label
Uplink port number
Network(s)
Network name or the name of the shared uplink associated with this port
Status
Shows the link status, link speed, and connectivity of the port. If the port is
unlinked and no connectivity exists, the cause is displayed. For more
information about possible causes, see "Port status conditions (on page
)."
Connector Type
Displays the physical type of the faceplate connector, type of pluggable
module if one is present, or "Internal" to indicate the inter-switch link is active
on the VC-Enet module.
LAG ID
Identifies the group of ports that have been aggregated together to form an
802.3ad Link Aggregation Group. This ID is unique only within a single
VC-Enet module, meaning the same LAG ID can be used on different VC-Enet
modules, but it is only meaningful for ports within the same VC-Enet module.
Connected to
Displays the MAC address of the device that this port is connected to on the
other end. The remote device must support LLDP to display this information.
Detailed Statistics
Click to display detailed statistics about this port.
The following table describes the columns within the Server Port Information table in the Bay Summary
screen.
Column
Description
Label
Server side port number (determined by the device bay and NIC)
Flex NIC
Flexible network interface card port
Physical server
Number of the device bay and a description of the installed server blade
- Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem